VEGA VEGASWING 51 - contactless electronic switch User Manual

Page 11

Advertising
background image

11

4 Mounting

VEGASWING 51 • - contactless electronic switch

41045-EN-130322

marking on the hexagon of VEGASWING 51. With this, you can check

the position of the tuning fork when screwing it in. When the hexagon

touches the seal, the thread can still be turned by approx. half a turn.

This is sufficient to reach the recommended installation position.
In adhesive and viscous products, the surfaces of the tuning fork

should protrude into the vessel to avoid buildup. Therefore sockets for

flanges and mountings bosses should not exceed a certain length.

30 mm

(1.18")

Fig. 5: Adhesive products

If VEGASWING 51 is mounted in the filling stream, unwanted false

measurement signals can be generated. For this reason, mount VE-

GASWING 51 at a position in the vessel where no disturbances, e.g.

from filling openings, agitators, etc., can occur.

To make sure the tuning fork of VEGASWING 51 generates as little

resistance as possible to product flow, mount the sensor so that the

surfaces are parallel to the product movement.

Inflowing medium

Flows