VEGA VEGASWING 51 - contactless electronic switch User Manual

Page 23

Advertising
background image

23

9 Supplement

VEGASWING 51 • - contactless electronic switch

41045-EN-130322

Output variable
Output

Contactless electronic switch

Modes min / max (changeover by electrical connection)

Ʋ Max.

Max. detection or overflow/overfill protection

Ʋ Min.

Min. detection or dry run protection

Voltage supply
Operating voltage

20 … 253 V AC/DC

Power consumption

max. 0.5 W

Electromechanical data
Valve plug ISO 4400

Ʋ Wire cross-section

1.5 mm² (0.06 in²)

Ʋ Outer cable diameter

4.5 … 7 mm (0.18 … 0.28 in)

Valve plug ISO 4400 with IDC method of termination

Ʋ Wire cross-section

for wire cross-section of 0.5 … 1 mm² (0.02 … 0.04 in²)

Ʋ Single-wire diameter

> 0.1 mm (0.004 in)

Ʋ Wire diameter

1.6 … 2 mm² (0.06 … 0.08 in²)

Ʋ Outer cable diameter

5.5 … 8 mm (0.22 … 0.31 in)

Ʋ Connection frequency

10 x (on the same cross-section)

Electrical protective measures
Protection rating

Ʋ Valve plug ISO 4400

IP 65

Ʋ Valve plug ISO 4400 with IDC method

of termination

IP 67

Overvoltage category

III

Protection class

I

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".

Advertising