ADC Transfer Functions

Figure 13 shows the unipolar transfer function for non-
temperature measurements, and Figure 14 shows the
bipolar transfer function used for temperature measure-
ments. Code transitions occur halfway between suc-
cessive-integer LSB values. Output coding is binary,
with 1 LSB = V

REFADC

/4096 for nontemperature mea-

surements, and 1 LSB = +0.125°C for temperature
measurements. All signed binary results use two’s com-
plement format.

ADC Conversion Scheduling

The MAX11008 ADC multiplexer scans and converts
the selected inputs in the order shown in Table 2 (see
the

ADC Conversion Register (ADCCON) (Write Only)

section) when more than one channel is selected. The
results are stored in the FIFO when in ADC monitoring
mode. The BUSY signal is set at the start and reset at
the end of a scan except when the continuous convert
bit is set at which time BUSY does not then respond to
ADC conversions.

Writing a conversion command before a conversion is
complete cancels the pending conversion. Avoid
addressing the device using the serial interface while
the ADC is converting.

ADC Clock Modes

The MAX11008 offers three conversion/acquisition
modes (known as clock modes) selectable through
configuration register bits CKSEL1 and CKSEL0.

If the ADC conversion requires the internal reference
(temperature measurement or voltage measurement with
internal reference selected) and the reference has not
been previously forced on (FBGON = 1), the device
inserts a typical delay of 72µs, for the reference to settle,
before commencing the ADC conversion. The reference
remains powered up while there are pending conver-
sions. If the reference is not forced on, it automatically
powers down at the end of a scan or when CONCONV in
the ADC Conversion register is set back to 0.

Internally Timed Acquisitions

and Conversions

Clock Mode 00

In clock mode 00, power-up, acquisition, conversion,
and power-down are all initiated by writing to the ADC
Conversion register and performed automatically using
the internal oscillator. This is the default clock mode.
The ADC sets the BUSY output high, powers up, and
scans all requested channels storing the results in the
FIFO if the ADCMON bit has been set. After the scan is

MAX11008

Dual RF LDMOS Bias Controller with

Nonvolatile Memory

______________________________________________________________________________________

25

FULL-SCALE TRANSITION

INPUT VOLTAGE (LSB)

BINAR

Y OUTPUT CODE

0

0000 0000 0001

0000 0000 0000

0000 0000 0010

0000 0000 0011

1111 1111 1101

1111 1111 1100

1111 1111 1110

1111 1111 1111

1 LSB = V

REFADC

/4096

1

2

3

4093

4095

V

REFADC

V

REF

ADC

Figure 13. ADC Transfer Function

TEMPERATURE (°C)

OUTPUT CODE

-256

+255

0

1000 0000 0000

1000 0000 0001

0000 0000 0001

0111 1111 1111

0111 1111 1110

0111 1111 1101

0000 0000 0000

1111 1111 1111

1000 0000 0010

1 LSB = +0.125°C

Figure 14. Temperature Transfer Function

ORDER OF SCAN

DESCRIPTION OF CONVERSION

1

Internal device temperature

2

External diode 1 temperature

3

Output of PGA 1 for current sense

4

Auxiliary input 1 (ADCIN1)

5

External diode 2 temperature

6

Output of PGA 2 for current sense

7

Auxiliary input 2 (ADCIN2)

Table 2. Order of ADC Conversion Scan