Table 12. alarm software configuration register – Rainbow Electronics MAX11008 User Manual

Page 52

Advertising
background image

MAX11008

Dual RF LDMOS Bias Controller with
Nonvolatile Memory

52

______________________________________________________________________________________

DATA BITS

BIT NAME

RESET STATE

FUNCTION

D[15:12]

Unused

X

Unused bits.

D11*

A2AVG

0

Channel 2 APC averaging and filtering bit.
Set to 1 to enable the APC averaging and filtering function for channel 2.
The source of the sample is controlled by the APCSRC2 field in the Software
Configuration register.

D10*

T2AVG

0

Channel 2 temperature averaging and filtering bit.
Set to 1 to enable the temperature averaging and filtering function for
channel 2. The source of the sample is controlled by the TSRC2 field in the
Software Configuration register.

D9*

A1AVG

0

Channel 1 APC averaging and filtering bit.
Set to 1 to enable the APC averaging and filtering function for channel 1.
The source of the sample is controlled by the APCSRC1 field in the Software
Configuration register.

D8*

T1AVG

0

Channel 1 temperature averaging and filtering bit.
Set to 1 to enable the temperature averaging and filtering function for
channel 1. The source of the sample is controlled by the TSRC1 field in the
Software Configuration register.

D7

TALARM2

0

Channel 2 temperature alarm enable bit. Set TALARM2 to 1 to enable the
channel 2 temperature alarm.

D6

TWIN2

0

Channel 2 temperature alarm window bit. Set to 0 for hysteresis mode, and
set to 1 for window mode. See the Hysteresis Mode and Window Mode
sections.

D5

IALARM2

0

Channel 2 current alarm enable bit. Set IALARM2 to 1 to enable the channel
2 current alarm.

D4

IWIN2

0

Channel 2 current alarm window bit. Set to 0 for hysteresis mode, and set to
1 for window mode. See the Hysteresis Mode and Window Mode sections.

D3

TALARM1

0

Channel 1 temperature alarm enable bit. Set TALARM1 to 1 to enable the
channel 1 temperature alarm.

D2

TWIN1

0

Channel 1 temperature alarm window bit. Set to 0 for hysteresis mode, and
set to 1 for window mode. See the Hysteresis Mode and Window Mode
sections.

D1

IALARM1

0

Channel 1 current alarm enable bit. Set IALARM1 to 1 to enable the channel
1 current alarm.

D0

IWIN1

0

Channel 1 current alarm window bit. Set to 0 for hysteresis mode, and set to
1 for window mode. See the Hysteresis Mode and Window Mode sections.

Table 12. Alarm Software Configuration Register

X = Don’t care.

*

Write only.

Advertising