Table 13d. v, Calculation trigger condition – Rainbow Electronics MAX11008 User Manual

Page 55

Advertising
background image

MAX11008

Dual RF LDMOS Bias Controller with

Nonvolatile Memory

______________________________________________________________________________________

55

Set SELFTIME to 1 and DOCAL to 1 to perform calibra-
tions of PGA1 and PGA2 on a self-timed periodic basis
(approximately every 13ms). When SELFTIME is set to
0, writing to PGACAL with DOCAL set to 1 manually
triggers PGA calibration.

ADC Conversion Register (ADCCON) (Write Only)

Write to the ADC Conversion register to select which
channels are converted and to set the ADC for continu-
ous conversion of each selected channel (see Table
20). Set CONCONV to 1 to configure the ADC to per-
form continuous conversions of the selected channels.

Bits D[6:0] select which channels are converted. Select
which channel is to be converted by setting the corre-
sponding bit to 1. Any channel that is set to 0 will not
be converted. Depending on the ADC clock mode that
is selected in the Hardware Configuration register (see
the

Internally Timed Acquisitions and Conversions

sec-

tion and Table 11), writing to the ADC Conversion reg-
ister initiates an ADC conversion of the selected
channel or the next selected channel in the sequence if
more than one channel is selected (see the

ADC

Conversion Scheduling

section). Bits D[15:8] are don’t-

care bits.

SOFTWARE CONFIGURATION

SETTINGS

V

GATE_

CALCULATION TRIGGER CONDITIONS

TCOMP_ = 1

APCCOMP_ = 1

APCSRC_1 = 0
APCSRC_0 = 0

• Temperature measurements vary enough to exceed the hysteresis settings

• A write command to the APC_ Parameter register
• A write command to the VSET register through the serial interface

TCOMP_ = 1

APCCOMP_ = 1

APCSRC_1 = 1
APCSRC_0 = X

• Temperature measurements vary enough to exceed the hysteresis settings

• Current-sense measurements or ADCIN_ samples vary enough to cause a new LUT

value to be retrieved (depends on PSIZE and INT values in the LUT Configuration
registers)

• A write command to the VSET register through the serial interface

TCOMP_ = 1

APCCOMP_ = 0

APCSRC_1 = X
APCSRC_0 = X

• Temperature measurements vary enough to exceed the hysteresis settings

• A write command to the VSET register through the serial interface

TCOMP = 0

APCCOMP = 1

APCSRC_1 = 0
APCSRC_0 = 0

• A write command to the APC_ register through the serial interface

• A write command to the VSET register through the serial interface

TCOMP = 0

APCCOMP = 1

APCSRC_1 = 1
APCSRC_0 = X

• Current-sense measurements vary enough to exceed the hysteresis settings

• A write command to the VSET register through the serial interface

TCOMP = 0

APCCOMP = 0

APCSRC_1 = X
APCSRC_0 = X

• A write command to the VSET register through the serial interface

Table 13d. V

GATE

_ Calculation Trigger Condition

X = Don’t care.

Advertising