Table 26. flag register – Rainbow Electronics MAX11008 User Manual

Page 65

Advertising
background image

MAX11008

Dual RF LDMOS Bias Controller with

Nonvolatile Memory

______________________________________________________________________________________

65

DATA BITS

BIT NAME

RESET STATE

FUNCTION

D[15:12]

Reserved

X

Reserved bits.

D11

ALUBUSY

1

ALU busy bit. Set to 1 when the MAX11008 is performing internal
calculations. Set to 0 after calculations are complete.

D10

RESTART

0

Restart flag bit. Set to 1 after a full software reset is performed. Returns to 0
after the Flag register is read. Set to 0 after initial power-up.

D9

FIFOEMP

0

FIFO empty flag bit. Set to 1 when FIFO is empty. Set to 0 when data is
placed into the FIFO.

D8

FIFOOVER

0

FIFO overflow/full flag bit. Set to 1 when in ADC monitoring mode and FIFO
overflow occurs. Returns to 0 when after Flag register is read. Set to 1 when
in LUT streaming mode and the FIFO is full. Returns to 0 after a data word
is moved out of the FIFO.

D7

HIGHI2

0

Channel 2 high current flag bit. Set to 1 when the channel 2 current-sense
measurement exceeds the channel 2 high current threshold and returns to
0 after the Flag register is read. When the INTEMP2 bit is set, this bit
functions as the internal temperature sensor’s alarm status.

D6

LOWI2

0

Channel 2 low current flag bit. Set to 1 when the channel 2 current-sense
measurement exceeds the channel 2 low current threshold and returns to 0
after the Flag register is read. When the INTEMP2 bit is set, this bit
functions as the internal temperature sensor’s alarm status.

D5

HIGHT2

0

Channel 2 high temperature flag bit. Set to 1 when the channel 2
temperature measurement exceeds the channel 2 high temperature
threshold and returns to 0 after the Flag register is read. When the
INTEMP2 bit is set, this bit is unused and may read as 1 or 0.

D4

LOWT2

0

Channel 2 low temperature flag bit. Set to 1 when the channel 2
temperature measurement exceeds the channel 2 low temperature
threshold and returns to 0 after the Flag register is read. When the
INTEMP2 bit is set, this bit is unused and may read as a 1 or 0.

D3

HIGHI1

0

Channel 1 high current flag bit. Set to 1 when the channel 1 current-sense
measurement exceeds the channel 1 high current threshold and returns to
0 after the Flag register is read.

D2

LOWI1

0

Channel 1 low current flag bit. Set to 1 when the channel 1 current-sense
measurement exceeds the channel 1 low current threshold and returns to 0
after the Flag register is read.

D1

HIGHT1

0

Channel 1 high temperature flag bit. Set to 1 when the channel 1
temperature measurement exceeds the channel 1 high temperature
threshold and returns to 0 after the Flag register is read.

D0

LOWT1

0

Channel 1 low temperature flag bit. Set to 1 when the channel 1
temperature measurement exceeds the channel 1 low temperature
threshold and returns to 0 after the Flag register is read.

Table 26. Flag Register

X = Don’t care.