Use of High Pressure Pump

ENGLISH

15

12.3 Spray nozzle / Output volume

A double nozzle (18) is supplied as standard
equipment with the sprayer.

The following general output data is valid for this
nozzle:

12.4 Excess spray chemical / Completing

spraying operation

Stop the engine of the high pressure sprayer as
soon as air is pumped through the nozzle (this can
be heard and seen by the formation of fog like
spray drift). At that point the remaining spray
chemical in the tank is less than 200 ml. Unless
you want to refill the tank and continue with the
spray operation, dilute the remaining spray volume
with 2 litres of water. Apply the dilution over the
already treated area.

Never operate the engine without liquid in the
spray tank. The pump will suffer damage if
operated dry.

After finishing the spray operation, stop the engine
by pressing the stop button (9) until the engine
stops. Let the engine cool down. Empty and clean
the machine according to section 13.4 "Emptying
and cleaning of chemical tank". Thoroughly wash
face and hands with water and soap. Remove the
work clothing after spraying. Clean work clothing
regularly.

Note:

After extended operating periods of the high
pressure sprayer, the engine and some parts
(such as the muffler) around the engine can get
very hot. To prevent any consequential damage
we recommend the running of the engine at idling
speed for a short time after the engine has been
used at full speed for longer periods before the
engine is shut down as described.

12.5 Spray tube holder

Spray Pressure

in bar

Output volume in l/min

5 1,0

10

1,7

20 2,0

30

2,4

Fig. 11