3.2. LED Indicators


Serial-Tx and Serial-Rx LED will flash accordingly when data is transmitted. For small data
transmissions, it may be hard to recognize the quick flashing action of the LED.

Table 3-2 The Parani-SD1000U LED Indicators

Indicator

Mode LED

Connect LED

Mode 0

Green

┏━━━━━

Mode 1

Green

(every 1 sec) ┏┓

Mode 2

Green

(every 3 sec) ┏┰┓

Mode 3

Green

(every 3 sec) ┏┰┰┓

Connected

Green

(every 1 sec) ┏┓


3.3. Serial Ports


The applicable settings for serial ports are as follows.

Table 3-3 The Parani-SD1000U Serial Port Settings

Serial Port Settings

Values

Baud rate

1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800,
921600

Data bite

8

Parity

No parity, Even parity, Odd parity

Stop bit

1, 2

Hardware Flow Control

Use, No Use


The values in box are the factory defaults. The flow control setting is configurable only through dip
switch.

3.4. Data Bit


Parani-SD1000U supports only 8 data bit. In the case of 7 data bit and even/odd parity, use SD 8 data
bit and none parity. At this time, master and slave are Parani-SD, Parani-ESD or Parani-MSP series.
But 7 data bit and none parity is not support.

3.5. Hardware Flow Control


Parani-SD1000U plugged into its host system transmits data from host to the other side Bluetooth
device. This data is saved temporarily in the internal buffer of Parani-SD1000U and sent repeatedly
until the transmission is completed packet by packet. When the radio transmission condition is not
good enough to send data promptly, it can cause a transmission delay. If the host sends more data
when the buffer is full, buffer overflow will make Parani-SD1000U malfunction consequently. In order
to prevent this buffer overflow, Parani-SD1000U works as follows.