3.3 Troubleshooting Application Problems

When the Configuration Wizard reports no errors but the PC application doesn't work, the following suggestions
may help identify the cause of the problem:

Use the Serial/IP Activity window to see if the Serial/IP COM port is being used when the application
runs. It is surprisingly easy to forget to change all application COM port settings to use Serial/IP COM
ports. For details, see the section

Monitoring Serial/IP COM Port Activity

.

Use the Serial/IP Trace window to closely inspect the data being read and written by the application. The
trace data is fairly self-explanatory, and it can be easy to diagnose a problem from this information. For
details, see the section

Tracing Serial/IP COM Port Data

.

Double-check if the application must have access to serial line status and control signals of serial ports.
This topic is covered in the previous section

Checking for Special Application Requirements

. If this is a

requirement of the application, you will need to use a serial server that supports the COM Port Control
protocol.