CR 194 One/Two-High Vacuum Limitamp

®

AR Control

Page 18

CR194 AR 400A, Stationary or Draw-out,

Outline Dimensions, Two-High, Top Cable Entry.

LOWER UNIT

UPPER UNIT

FRONT

TOP VIEW

PLENUM

FRONT VIEW

L.H.SIDE VIEW

M

M

613

16

1738

6

258

2 5

16

212

6

6

N

FLOOR PLAN

3

4

TYP.

6

6

2

TYP.

112

C

11 3

16

C

C

2015

16

4314

712

6813

16

52

612

612

14 3

16

1213

16

E

B1

PLENUM

FRONT

32

G

2-HI

LOWER UNIT

UPPER UNIT

36

42

TOP CABLE ENTRY

-2200 lbs

998 Kg

FRONT

112

90

24

C

Enclosure Outline dimensions 2400-7200 Volts

CR194 AR 400A, 2 High, 36" Wide
(Stationary or Draw-out)-TOP CABLE ENTRY

J

GE Limitamp

®

AR Medium Voltage Motor Control

Enclosures

E4A

D

D

D

D

1811

16

26 9

16

3438

6378

7558

613

16

412

634

7

1034

612

18

1738
18 1

16

H

48

REV: 01

T1

T2

T3

T1

T2

T3

T1-T3

T2

T1

T2

T3

* *

*

*

*

*

*

*

*

*

*

4278

513

16

B2

11

11

L1

L3

L2

L1

L2

L3

712

Notes:
B1 — AC Power Bus, 1200A
B2 — AC Power Bus, 3000A

C — Control Lead Terminal Board

D — Motor Lead Terminal Connection
E — Ground Bus Terminal Connection

G — Space Required to Open Doors 135°

H — Four-foot Aisle for Contactor Removal

J — Mounting Holes for 1/2" Diameter
Anchor Bolts

M — Recommended Position for Incoming
Motor Conduit
N — Recommended Position for Incoming Control Conduit

* — Indicates Terminal Location - Approximate for Cable Length
— Approximate Weight

LOWER UNIT

UPPER UNIT

FRONT

TOP VIEW

PLENUM

FRONT VIEW

L.H.SIDE VIEW

M

M

613

16

1738

6

258

2 5

16

212

10

6

N

FLOOR PLAN

3

4

TYP.

6

6

2

TYP.

112

C

15 3

16

C

C

2015

16

4314

712

6813

16

52

612

612

14 3

16

1213

16

E

B1

PLENUM

FRONT

36

G

2-HI

LOWER UNIT

UPPER UNIT

40

42

TOP CABLE ENTRY

-2450 lbs

1112 Kg

FRONT

112

90

24

C

Enclosure Outline dimensions 2400-7200 Volts

CR194 AR 400A, 2 High, 40" Wide
(Stationary or Draw-out)-TOP CABLE ENTRY

J

E5A

GE Limitamp

®

AR Medium Voltage Motor Control

Enclosures

D

D

612

1034

18

1738

18 1

16

D

D

1811

16

26 9

16

3438

6378

7558

7

634

4 9

16

613

16

H

48

REV: 01

T1

T2

T3

T1

T2

T3

T1-T3

T2

T1

T2

T3

* *

*

*

*

*

*

*

*

*

*

4278

513

16

B2

11

11

L1

L3

L2

L1

L2

L3

712

Notes:
B1 — AC Power Bus, 1200A
B2 — AC Power Bus, 3000A

C — Control Lead Terminal Board

D — Motor Lead Terminal Connection
E — Ground Bus Terminal Connection

G — Space Required to Open Doors 135°

H — Four-foot Aisle for Contactor Removal

J — Mounting Holes for 1/2" Diameter
Anchor Bolts

M — Recommended Position for Incoming
Motor Conduit
N — Recommended Position for Incoming Control Conduit

* — Indicates Terminal Location - Approximate for Cable Length
— Approximate Weight

Figure 39. Top Cable Entry 400A