4.4 CUSTOMER INTERFACE BOARD (OPTION)

WARNING !

The installation and cabling of the options must be performed by
QUALIFIED SERVICE PERSON
.

Serial port J3 - RS232 (sub - D - female 9 pin)

Total remote management of the system using new

generation software JUMP (Java Universal Management

Platform) for system protection and management of
systems using GE UPS’s.

JUMP system is written in JAVA and supports virtually all
platforms having JAVA runtime environment.

Pin 2: TX (out)


Pin 3
: RX (in)


Pin 5
: GND

J2 (sub – D female 25p) – Output signals on voltage-free contacts

J2 / 1, 2, 3

NO, C, NC

Utility failure

(default Parameter RL=1)

J2 / 4, 5, 6

NO, C, NC

Load on inverter

(default Parameter RL=3)

J2 / 7, 8, 9

NO, C, NC

Stop operation

(default Parameter RL=5)

J2 / 14, 15, 16

NO, C, NC

Load on utility

(default Parameter RL=2)

J2 / 17, 18, 19

NO, C, NC

General alarm (NO)

(default Parameter RL=4)

J2 / 20, 21, 22

NO, C, NC

Buzzer

(default Parameter RL=6)

Signals on terminals X1 and on connector J2 are in parallel and

therefore not separated galvanically from each other.
The programmable signals on X1
and J2 will be disabled with Q1

open, with the exception of the signals for:

16 – Manual bypass ON
24 – Relay output ON

25 – Relay output OFF

26 – EPO

X1 – Output signals on voltage-free contacts

X1 / 1, 2, 3

NO, C, NC

Utility failure

(default Parameter RL=1)

X1 / 4, 5, 6

NO, C, NC

Load on inverter

(default Parameter RL=3)

X1 / 7, 8, 9

NO, C, NC

Stop operation

(default Parameter RL=5)

X1 / 12, 13, 14

NO, C, NC

Load on utility

(default Parameter RL=2)

X1 / 15, 16, 17

NO, C, NC

General alarm (NO)

(default Parameter RL=4)

X1 / 18, 19, 20

NO, C, NC

Buzzer (default

Parameter

RL=6)

X2 – Terminals EPO connection (Emergency Power Off)

X2 / 1, 2 or J2 / 12, 25

NC

EPO (Emergency Power Off)

LPS33U

_Cust

omer i

nterfac

e_01

12

3

4

5

6

789

10

11

16

15

14

13

12

22

21

20

19

18

17

J3

J2

X1

2
1

JP3
X2

Fig. 4.4-1 Customer Interface

C

=

Common

NO

=

Normally Open

NC

=

Normally Closed

To enable this function, remove jumper JP3 on the Customer

Interface and the cable on the terminal X2 / 1, 2.
(See Fig. 4.4-1).
Verify if the cable on the terminal X7 / 1, 2 and jumper JP5 on the

P1 – Control board are OFF (see Fig. 4.4-3).

Programmable functions on input contacts

X1/10, 21 or J2/10, 23

Programmable

(default Parameter = RL1)

X1/11, 22 or J2/11, 24

Programmable / Generator ON (NO)

(default Parameter = RL2)