Using the command/response tables, Symbol definitions, Command/response table for sis commands – Extron Electronics MLC 206 AAP EC User Guide User Manual

Page 35: Using the command/response tables -3, Symbol definitions -3, Command/response table for sis commands -3, 3 medialink controllers • serial communication

Advertising
background image

4-3

MediaLink Controllers • Serial Communication

E16 – Unit is busy
E23 – Checksum error.

Using the command/response tables

The command/response tables below and on the following pages list valid
command ASCII codes, the MLC’s responses to the host, and a description of the
command’s function or the results of executing the command. Upper and lower
case characters may be used interchangeably in the command field.

The ASCII to HEX conversion
table at left is for use with the
command/response tables.

ASCII to HEX Conversion Table

ASCII to Hex conversion table

X3

=

Volume adjustment range (0 through 100%)

X4

=

Relay number (1 through 3)

X5

=

Relay status

0 = off
1 = on

X6

=

Controller firmware version (listed to

two decimal places e.g.: x.xx)

X7

=

On/off status

0 = off/disable
1 = on/enable

Symbol definitions

=

CR/LF (carriage return/line feed) (hex 0D 0A)

=

Space

Esc

=

Escape key

X1

=

Specific input number (0 through 6 maximum)

0 = no connection
1 = input 1, 2 = input 2, and so forth

X2

=

Display power status (0 through 3)

0 = display power is off
1 = display power is on
2 = display is powering down
3 = display is powering up

Command/response table for SIS commands

Command

ASCII Command Response

Additional description

(host to MLC)

(MLC to host)

Input/button selection

Select an input/button

X1

!

Chn

X1

Select input

X1

.

Btn

X1

Select button

X1

(if button isn’t

part of the switching rotation).

Example:

6!

Chn6

Example:

select input 6.

Display (projector) power

Turn display power on

1P

Pwr

X2

On (discrete).

Turn display power off

0P

Pwr

X2

Off (discrete).

View display power status

P

Pwr

X2

Show the display power status.

Example:

P

Pwr2

Relay functions

Turn relay off

X4

*0O

Rly

X4

*0

Toggle relay number

X4

off.

Example:

3*0O

Rly30

Set relay 3 to off.

Turn relay on

X4

*1O

Rly

X4

*1

Toggle relay number

X4

on.

View relay status

X4

O

Rly

X4

*

X5

Show the status of relay

X4

.

Example:

2O

Rly2*1

Show the status of relay 2.