Command/response table for advanced instructions, Based control program) -8, Serial communication, cont’d – Extron Electronics MLC 206 AAP EC User Guide User Manual

Page 40

Advertising
background image

Serial Communication, cont’d

MediaLink Controllers • Serial Communication

4-8

Command

Hex. command

Response

Additional description

(host to MLC)

(MLC to host)

Send/receive data to/from page 0 memory

Send

80 A0 [16k bytes of data]

Dnl0

The host downloads 16k bytes
of binary data to page 0 of the
MLC’s memory.

Receive

80 A1

The MLC sends 16k bytes of
binary data to the host.

Send/receive data to/from page 1 memory

Send

80 A2 [16k bytes of data]

Dnl1

The host downloads 16k bytes of binary

data to page 1 of the MLC’s memory.

Receive

80 A3

The MLC sends 16k bytes of
binary data to the host.

Send/receive a segment (256 bytes) of data (a segment relating to a single button)

Send

80 A6

??

[256 bytes of data]

Seg0

The host sends 256 bytes of
binary data to the MLC.

Receive

80 A7

??

The MLC sends 256 bytes of
binary data to the host.

Initiate or abort IR learning

Learn ready

80 B0

??

LrnRdy

Initiate IR learning.

LrnTimOut

Timeout during IR learning.

LrnRetry

Retry IR learning.

(Aim remote

control at MLC, press button again.)

LrnFail

IR learning has failed.

LrnOK

IR learning has succeeded.

Abort learning

80 B1

Lrn Abort

Abort IR learning.

Set pass-through/normal mode

Set to pass-through mode

80 C0

Hst1

Set the MLC to RS-232 pass-
through mode. RS-232 commands
will go directly to a connected
Extron MLS switcher for direct
control of switcher settings.

Set to normal mode

80 C1

Hst0

Set/reset the MLC to normal
mode. RS-232 commands are
processed by the MLC.

Activate a memory block (segment)/emulate a button press

Activate a block

80 D0

??

IRSnd*

??d

Activate/trigger a memory
block. (Send the command
stored at that address).

Emulate a button press

80 D1

??

Btn

??d

Simulate pressing a button.
(Send the command and/or
perform the function [relay
triggering] stored in the block.)

??

indicates the block number in hex notation where

??

can be 0 to 7F (hex)

(0 to 127 decimal).

??d

indicates the block number in ASCII numeric notation.

The responses shown are ASCII.

Command/response table for advanced instructions
(for the Windows-based control program)

Data downloads/uploads are initiated by sending a series of hex commands to the
host RS-232 port of the MLC. The Windows-based control program uses these
commands mainly to load and save driver data and system configuration settings.