Serial communication, cont’d – Extron Electronics MLC 206 AAP EC User Guide User Manual

Page 50

Advertising
background image

Serial Communication, cont’d

MediaLink Controllers • Serial Communication

4-18

The trigger and destination buttons change to lighter shades of green or red
once they have been associated with each other.

Tied buttons can be identified by their lighter shade of red or green, and by the
destination button number displayed on the tied trigger and destination
buttons. In the example above, pressing the MLC’s input button 1 will also
cause the VCR Play command to be issued.

Relays associated with a destination button will not be executed when the
trigger button is pressed.

6.

Repeat steps 4 and 5 for all desired pairs of trigger and “destination” buttons.

7.

To remove (undo) a tie, click on and drag the trigger button to the trashcan,

then release the button and confirm the unlinking.

Advertising