Serial communication, cont’d, Medialink controllers • serial communication 4-4 – Extron Electronics MLC 206 AAP EC User Guide User Manual

Page 36

Advertising
background image

Serial Communication, cont’d

MediaLink Controllers • Serial Communication

4-4

Volume adjustment

Set the output volume

X3

V

Vol

X3

Specify the volume for the
audio output.

Example:

82V

Vol082

Example: set volume to 82.

Increment

(increase audio output)

+V

Vol+

Increment projector’s audio
output (if set for projector audio
increment/decrement mode).

Vol

X3

Increase projector’s or
switcher’s audio output.

Decrement

-V

Vol-

Decrement projector’s audio
output (if set for projector audio
increment/decrement mode).

Vol

X3

Decrease audio output.

View the volume level

V

Vol---

Show the projector’s audio level
(if set for projector audio
increment/decrement mode).

Vol

X3

Show the output volume.

Audio mute (overall)

Mute on

(MLS fixed & variable audio outputs)

1Z

Amt1

Mute all audio outputs.

Mute off

(MLS fixed & variable audio outputs)

0Z

Amt0

Unmute all audio outputs.

View the audio mute status.

Z

Amt

X7

Show the status of audio mute.

Firmware version, part number & information requests

Query firmware version number

Q

Ver

X6

Show the controller firmware
version.

Request part number

N

N60-385-01

Show the MLC’s part #.

Request general info.

I

(see below)

Show the MLC’s status.

Chn • K1## • K2## • K3## • K4## • MLS0 • Rly1* • Rly2* • Rly3* • Vol

X1

X5

X5

X5

X3

Input # X1 is

selected/active.

Volume is

set to X3 .

Remote control

module 1 has

parameters of ##.

Remote control module 4

has parameters of ##.

Relay 1 is set to X5 (on or off).

Relay 3 is set to X5 .

Relay 2 is set to X5 .

Remote control
module 3 has
parameters of ##.

Remote

control

module 2 has

parameters of ##.

## indicates the module type.

00 = not present
01 = IRCM-VCR
02 = IRCM-DVD
03 = IRCM-DVD+
04 = ACM-Level

05 = ACM-Tone
06 = RCM-SC
07 = RCM-SCLT
08 = IRCM-Tape

11 = IRCM-DV+
99 = unrecognized

module

MLS switcher status (what kind
of MLS or other device is slaved):
0 = no MLS
1 = MLS 306,
2 = MLS 506
3 = MLS 506 MA (70V)
4 = MLS 506 SA
5 = MLS 506 MA (100V)
6 = MLS 100 A
7 = MLS 103 V

8 = MLS 103 SV
9 = MLS 102 VGA

10 = MLA-VC10

Request projector configuration

K

(16 char + spc + 16 char)

Show which projector driver is
being used. The response is a
string of 16 characters + space +
16 characters (total = 33
characters).

Example:

K

•••NEC•MT1050••• • IR•REVA•••••••••

Zap (reset to default settings)

Zap all MLC settings/memories

Esc

zXXX

ZapXXX

Reset everything: all settings,
adjustments, and drivers to the
factory default.

Command/response table for SIS commands (continued)

Command

ASCII Command Response

Additional description

(host to MLC)

(MLC to host)

Advertising
This manual is related to the following products: