System 5 IP Switchers • Hardware Setup

System 5 IP Hardware Setup, cont’d

2-6

System 5 IP Switchers • Hardware Setup

2-7

For infrared (IR) output

, wire an IR Emitter (2 emitters,

maximum, per port)

as shown below for a modulated signal

and ground.

S G S G S G S G

IR/SERIAL OUT

A

B

C

D

IR Emitter 1

White Striped Wire

100'

(30.5 m)

G = Ground

S = Signal (IR)

See the System 5 IP Series User's Manual for details on how to set

up these ports for IR or RS-232 control.

c

CM/IR/SCP port

— You can connect up to four Extron control

modules (IRCMs, ACMs, RCMs), one Extron IR Link infrared

signal repeater, and/or up to two Extron SCP 104 or SCP 226

control pads to this port to allow remote control of the

System 5 IP switcher or other items. A maximum of seven

devices can be connected to this port.

The SCP 104 or SCP 226 Secondary Control Panel replicates

most of the switcher’s front panel controls. The control pad

can receive IR signals from an optional IR 402 remote control

and send them to the switcher. Control modules can be used to

control VCRs, DVD players, tape decks, a projector lift, or screen

control. Refer to the appropriate device’s user’s manual.

The control modules, IR Link, and SCPs can be daisy chained,

as shown in the following diagram. Extron CTL (Comm-Link)

cable is recommended for these connections. Use the following

diagram as a wiring guide.

SCP 226

200' (61 m) max.

to Last Device

E

C

B

A

SCP Communication

IRCM, ACM, RCM

+12 VDC

Ground ( ) & Drain Wire

C

B

A

Ground ( )

IRCM/ACM/RCM

+12 VDC

Maximum =
4 Control Modules
(4 Module Addresses)

Control modules include IRCM,
ACM, RCM, and CM models.

DVD & VCR CONTROL

PLAY NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

IRCM-DV+

G

+V

CM IRSCP

E

C

B

D

A

System 5 IP Switcher
Rear Panel

Extron CTL or CTLP Cable Color Code:

Ground ( ) & Drain Wire

E

D

C

B

A

SCP Communication

Modulated IR (for IR Link)

Control Module Communication

+12 VDC

=

White

=

Black & Drain Wire

=

Violet

=

Red

VOLUME

SCP 226

IR

DISPLAY

Extron

1

2

3

4

5

6

ON

OFF

PIC

MUTE

AUTO

IMAGE

PC

VCR

DVD

LAPTOP

DOC
CAM

N

The maximum total distance between the System 5 IP and

a connected device is 200’ (61 m).

N

Extron recommends that you connect the cable’s drain

wire to the ground pin at both ends. This reduces EMI

interference.

d

Relay ports — Via Global Configurator, each relay can be

associated with a front panel button (projector on/off buttons,

function buttons, or input selection buttons) or can be operated

independently.

2

1

C

C

4

3

C

6

5

C

RELAYS

B

A

2

1

C

C

4

3

C

6

5

C

RELAYS

B

A

2

1

C

C

4

3

C

6

5

C

RELAYS

B

A

Group B

Group C

Group A

Common

Relay 4

Relay 3

Common

Relay 6

Relay 5

Common

Relay 2

Relay 1

These relays are normally open by default. They can be

configured via SIS commands or Global Configurator to operate

as follows:

on

relay closes and stays closed until otherwise

instructed

off

— relay opens and stays open until otherwise instructed