System 5 IP Switchers • Hardware Setup

System 5 IP Hardware Setup, cont’d

2-10

System 5 IP Switchers • Hardware Setup

2-11

The pin assignments of this connector are as follows:

Pin RS-232 function Description

1

No connection

2

Tx

Transmit data

3

Rx

Receive data

4

No connection

5

Gnd

Signal ground

6

No connection

7

No connection

8

No connection

9

No connection

The front panel 2.5 mm mini stereo connector Config port serves

the same function as this rear panel port but is independent

from it. You can use the Extron 9-pin D to 2.5 mm stereo mini

TRS RS-232 cable (part #70-335-01).

g

Reset button and LED

— Pressing this recessed button causes

various IP functions and Ethernet connection settings to be reset

to the factory defaults. See chapter 2 in the System 5 IP Series

User's Manual

for details.

R

Reset
Button
(Recessed)

Reset

LED

Front Panel Features and Basc Operaton

A System 5 IP can be set up and operated by using:
• The front panel controls.
• An Extron control pad, such as the SCP 104, or SCP 226.
Most settings can be adjusted only through a host computer

using Extron’s Simple Instruction Set

(SIS

) or

Global Configurator. For details on setup and control via RS-232

or Ethernet, see chapters 4 and 5 in the System 5 IP Series User's

Manual

.

N

Switcher settings can be adjusted via the front panel.

N

Any control settings must be adjusted via

Global Configurator.

SYSTEM 5 IP

PC

DOC

CAM

VCR

PIC

MUTE

ON

OFF

MENU

NEXT

AUTO

IMAGE

DVD

LAPTOP

PC VIDEO

INPUT 5

MAX

MID

VOLUME

AUDIO

ADJUST

MIN

2

3

4

5/ PC

DISPLAY

1

INPUT SELECTION

CONFIG

IR

SYSTEM 5 IP

PC VIDEO

INPUT 5

AUDIO

CONFIG

IR

3

10

10

8

6

4

5

7

2

1

9

System 5 IP with FPC

System 5 IP without FPC

System 5 IP with FPC

System 5 IP without FPC

2

1

Control ports

a

IR receivers

— The larger infrared receiver (on the left) accepts

IR signals from the Extron IR 402 infrared remote control for

controlling the switcher.

Use the smaller receiver (on the right) for receiving and

“learning” codes from other devices’ remote controls. The

System 5 IP uses learned IR signals to control devices such as

VCRs or DVD players. Refer to chapter 4, "Software- and Web

Page-based Setup and Control" of the System 5 IP Series User's

Manual

and the IR Learner Help file for details. This receiver

accepts infrared signals from 30 kHz to 62 kHz.

b

Config port

— This port is a front panel version of the rear panel

Configuration/RS-232 port, and it is independent of the rear

panel port.

Buttons

The System 5 IP with FPC (front panel control) has backlit

buttons, and the non-FPC model has an unlit input 5 selection

button only. The button caps are removable so the button labels

can be changed.

c

Projector On/Off buttons — After they have been configured,

press the On button to turn the display device on, and press

the Off button to power it off. Only one of these two buttons

can be selected (active) at once. Via Global Configurator,

other functions and relays can be associated with each of these

buttons.

Advertising