Setting the torque switching, 1 setting, 2 checking the torque switches – AUMA Electric part-turn actuators SG 05.1 - 12.1_SGR 05.1 - 12.1 NORM User Manual

Page 18: Torque setting 18, Tripping torque 18, Setting the duo limit switching (option)

Advertising
background image

14.

Setting the torque switching

14.1 Setting

.

The set torque must suit the valve!

.

This setting must only be changed with the consent of the
valve manufacturer!

.

Loosen both lock screws O at the torque dial (figure L).

.

Turn torque dial P to set it to the required torque (1 da Nm = 10 Nm).

Example:

Figure L shows the following setting:

90 ft lbs. for direction CLOSE

95 ft lbs. for direction OPEN

.

Tighten lock screws O again

.

The torque switches can also be operated in manual
operation.

.

The torque switching acts as overload protection over full
travel, also when stopping in the end positions by limit switch-
ing.

14.2 Checking the torque switches

The red test buttons T and P (figure K-1) are used for manual operation of the

torque switches:

.

Turning T in direction of the arrow TSC (DSR) triggers torque switch CLOSED.

.

Turning P in direction of the arrow TSO (DOEL) triggers torque switch OPEN.

.

If a DUO limit switching (optional) is installed in the actuator, the intermediate

position switches will be operated at the same time.

18

Part-turn actuators SG 05.1 – SG 12.1 / SGR 05.1 – SGR 12.1
AUMA NORM

Operation instructions

Ft. Lbs

Ft. Lbs

70

80

100

110

90

110

100

80

70

90

Figure L: Torque switching heads

Setting CLOSED

Setting OPEN

O

O

P

O

Advertising