12 error management and status list – MoTeC M1 Tune User Manual User Manual

Page 58

Advertising
background image

User Manual

USING M1 TUNE

Printed documents are not controlled

Page 57

11.12 ERROR MANAGEMENT AND STATUS LIST

Note:

Sensors not in use should be set to disabled where possible so that the Error
Status list, which is displayed in the Status window, is only used for genuine

errors.

M1 Tune senses that a channel has gone into error when its value goes outside the configurable
channel parameter limits.

The channel parameter limits are configured within the sensor settings, using the fault low and
high limits.

Note:

It is also important to set a reasonable default value for the sensor parameter. If
the channel goes into fault, the sensor will report its value to be this default value.
Consider how this value will affect the running engine in the event of a channel

fault.

How these errors are displayed is shown below.

When an error occurs, the channel parameter and its value are added to an Error Status list and
the following popup displays to notify the user of the change to the list of errors.

The popup lists the current number of errors, but only appears if there has been a change to the

number of errors.