Analog voltage inputs – MoTeC SDL User Manual

Page 11

Advertising
background image

MoTeC

Overview

9

• 2 Wheel Speed

Expander Inputs

Additionally one E888 expander may be connected to read from 8 K-type
thermocouples.

Internal Sensors

The SDL also includes internal sensors for G-Force Lateral, G-Force Vertical,
Battery Voltage and SDL Internal Temperature.

Sensors

Different types of sensors are available to suit different types of
measurements.

Sensors convert a physical measurement (e.g. Pressure) into an electrical
signal (e.g. Volts). Different types of sensors generate different types of
electrical signals. For example most temperature sensors convert the
temperature into a variable resistance signal which may be measured by the
SDL Temperature inputs, however most wheel speed sensors generate a
variable frequency signal which must be connected to either a Digital input or
a Speed input.

Calibration

Calibration is the process of converting the electrical value, e.g. Volts into a
number that represents the physical value, e.g. Temperature.

All inputs can be calibrated to suit the connected sensor.

The calibrations can be selected from a number of predefined calibrations
provided by MoTeC, or they can be entered by the user.

Analog Voltage Inputs

The 8 Analog Voltage inputs are normally used to measure the signals from
analog voltage type sensors, i.e. sensors with variable voltage outputs, such
as:

• Rotary or linear potentiometers
• Signal conditioned 3 wire pressure sensors
• Thermocouple

amplifiers

• Accelerometers

Advertising