Lambda input, Switch inputs, Motec appendices 47 – MoTeC SDL User Manual

Page 49: Calibration accuracy

Advertising
background image

MoTeC

Appendices

47

Measurement Voltage Range: 0 to 15 V

• Note that voltages outside this range may affect the readings on other

inputs.

Input Resistance: 1000 ohms pullup to 5V sensor supply + 100k to 0V

Resolution: 3.74 mV

Measurement Methods: Ratiometric, Absolute, Variable Resistance, Off/On

Update Rate: 500 times / second

Filter: 150Hz 1

st

order

Calibration Accuracy

Gain (Ratiometric operation) 0.05%

max

Gain (Absolute operation)

0.15% max

Offset

± 6 mV max

Linearity

± 6 mV max

Temperature Stability

60 ppm/

°C max

Calibration Schedule

12 Months

Lambda Input

Type: Wide Band MoTeC

Measurement Range: 0.75 to 1.50 Lambda (or 0 to 1V)

Accuracy: 1.5 % up to 1.20 Lambda

Update Rate: 100 times / second

Switch Inputs

Suitable for: Switch to 0V, or Off / On Voltage signal

Pullup Resistor: 4700 ohms to 5V

Voltage Range: 0 to 15V

Positive Trigger Threshold: 3.5 V max

Negative Threshold: 1.0 V min

Hysteresis: 0.5 V Min

Measurement Methods: Off/ On only