Analog input sampling, 50 appendices, Speed input modes – MoTeC SDL User Manual

Page 52

Advertising
background image

50 Appendices

Pulse Width 1 usec

Measures pulse high time

Resolution: 1 usec

Maximum: 32 msec

Pulse Width 100 usec

Measures pulse high time

Resolution: 100 usec

Maximum: 3.2 sec

Speed Input Modes

HALL Mode

Suitable for switch to 0V, Logic signal or open collector device (eg Hall
Switch)

Pullup Resistor: 4700 ohms to 5V

Voltage Range: 0 to 15V

Positive Trigger Threshold: 3.0 V max

Negative Threshold: 2.8 V min

Hysteresis: 0.19 V Min

MAGNETIC Mode

Suitable for: Two wire magnetic sensor (Variable reluctance sensor)

Input Resistance: 100k ohms to ground (No Pullup)

Voltage Range: -100V to +100V

Programmable trigger levels

Analog Input Sampling

The following specifies the order in which the Analog input channels are
sampled and the time between samples.

Inter channel period is 14usec, except that for every 8 channels there is a
60usec gap.

Advertising