Appendix d: input characteristics, Analog voltage inputs, Analog temp inputs – MoTeC SDL User Manual

Page 48: 46 appendices, Calibration accuracy

Advertising
background image

46 Appendices

Appendix D: Input Characteristics

Analog Voltage Inputs

Suitable for: Potentiometers, Voltage output sensors & Variable resistance
sensors with a pullup resistor

Measurement Voltage Range:

Inputs 1 to 4:

0 to 5.5 V

Inputs 5 to 8:

0 to 15.3 V

• Note that voltages outside this range may affect the readings on

other inputs.

Input Resistance: 100k ohms to 0V

Resolution:

Inputs 1 to 4:

1.35 mV

Inputs 5 to 8:

3.74 mV

Measurement Methods: Ratiometric, Absolute, Variable Resistance, Off/On

Update Rate (Inputs 1 to 4): 1000 times / second (for anti-aliasing)

Update Rate (Other inputs): 500 times / second (for anti-aliasing)

Filter: 150Hz 1

st

order

Calibration Accuracy

Gain (Ratiometric operation) 0.05%

max

Gain (Absolute operation)

0.15% max

Offset

± 6 mV max

Linearity

± 6 mV max

Temperature Stability

60 ppm/

°C max

Calibration Schedule

12 Months

Analog Temp Inputs

Suitable for: 2 wire variable resistance sensors and some voltage output
sensors.

Advertising