53

Cable

An Ethernet RJ45 socket, connecting to a standard Ethernet cable, is
provided on:

• #62202 SDL3 loom
• #61131 Ethernet cable, unterminated, 2 metre
• #61132 Ethernet to Autosport pins cable, 1.8 metre

CAN Bus Wiring Requirements

• The CAN bus should consist of a twisted pair trunk with 100R (0.25 watt)

terminating resistors at each end.

o

If the CAN bus is less than 2 metres (7 ft) long, a single termination

resistor may be used.

• The preferred cable for the trunk is 100R data cable.
• The maximum length of the bus is 16 metres (50 ft)
• CAN devices (such as MoTeC Dash Loggers, ECUs etc.) may be

connected to the trunk with up to 500 mm (20 in) of twisted wire.