62 appendices, Vimcom" errors – MoTeC ESDL3 User Manual

Page 66

Advertising
background image

62 Appendices

8

OVERRUN

Receive or transmit overrun error. In the
receive case a byte was received before the
previous byte was read indicating that the
processor is too busy to read the message.
In the transmit case the transmit buffer is full
which could happen if the CAN bus is too
busy.

256

BAD CONFIG

The device configuration is not valid (e.g.
overlapping CAN addresses)

512

NO DATA

A valid message header was not found -
either there is a wiring fault or comms is
setup incorrectly, (problem could be at either
end). E.g.: transmit and receive CAN IDs do
not match.

1024

CHECKSUM

Only generated when used with an Async
Expander. See RS232 errors

2048

WRONG DATA

Only generated when used with an Async
Expander or E888/E816 Expander. Async
Expander: Could not decode the protocol.
E888/E816: Compound ID incorrect.

4096

BUS WARNING

More than 96 errors have occurred on the
CAN bus. Check wiring and termination
resistors. The CAN bus may still be
operational.

8192

BUS OFF

More than 255 errors have occurred on the
CAN bus. CAN communications is
suspended when this error occurs. Check
wiring, termination resistors and the CAN
baud rate. Also check that CAN HI and CAN
LO are correct (not swapped).

16384

CAN TRANSMIT

CAN bus transmit warning

"VIMCOM" Errors

Errors generated by "VIMCOM" devices (SVIM, Dash Loggers).
Note:

VIMCOM devices are connected via CAN.

Dash Logger Errors (SDL3)
These errors are generated by the Dash Logger's communications system.

2

FRAMING

Incorrect number of samples received.

Advertising
This manual is related to the following products: