Changing protocol information, 1 accessing the dip switches, 2 setting the camera id – eLine Technology ANPTZ-70-10DN User Manual

Page 11: En gl is h

Advertising
background image

5

Changing Protocol Information

En

gl

is

h

3. CHANGING PROTOCOL INFORMATION

The DIP switches on the bottom of the camera control 3 values:
1. The ID of the camera, which allows the DVR/keyboard controller to

identify different PTZ cameras.

2. The protocol, which is the language that allows the camera and DVR/

keyboard controller to speak to each other (e.g. Pelco D).

3. The baud rate, which is the frequency of communications.

The illustration below shows the default values of the DIP switches.

Default ID: 1
Default Baud Rate: 2400
Default Protocol: Pelco-D

6

Changing Protocol Information

3.1 ACCESSING THE DIP SWITCHES

The DIP switches are located on the bottom of the camera. To access the

DIP switches, you must remove the camera from the wall mount. Rotate

the dome cover counterclockwise to remove. Remove the base

attachment screws (3x) and lift the camera from the camera base. See

illustration below.

Removing the camera from the wall mount

3.2 SETTING THE CAMERA ID

Camera ID is set using the larger DIP switch panel with 8 switches. Each

switch represents a binary digit (i.e. switch #1=1, #2=2, #3=4, etc.).

Camera ID can be anything between 1-255. See the address example

table on the next page.

Camera ID DIP Switches

You cannot use the same ID for more than 1 PTZ

camera.
You cannot set an ID with a value of 0.

IMPORTANT

eLineTechnology.com

Advertising
This manual is related to the following products: