En gl is h – eLine Technology ANPTZ-70-10DN User Manual

Page 31

Advertising
background image

25

Using the OSD Menu

En

gl

is

h

ALARM TYPE [Normal OPEN(N.O) / Normal CLOSE](N.C)]: Sets

sensor input type.

ALARM ACTION [NOT USED/HOME/PRESET/GROUP/PATTERN]: You

can assign an action for each Alarm input (Preset, Swing, Pattern and

Group).

5.3.3 PRESET SETUP

A maximum 127 of positions can be stored as presets. Preset numbers

can be assigned from 1 to 128.
NOTE: Preset "95" is reserved for starting the main menu.
Presets can be set using keyboard shortcuts or the OSD menu.

To set presets using keyboard shortcuts:

• Press [1~128] then press [Set] for 2 seconds.

To go to presets using keyboard shortcuts:

• Press [1~128] then press [Preset].

To set presets using the OSD menu:
1. Go to the Preset Setup menu (Menu>Dome Camera Setup>Preset

Setup).

2. Configure the following:

PRESET Number [1~128]: If a selected preset is already defined,

camera moves to pre-defined position and preset characteristics

show on monitor. If a selected preset is not defined, UNDEFINED

shows on monitor.

26

Using the OSD Menu

EDIT PRESET SCENE: Press [Near] to redefine current Preset scene

position. Then use the joystick to edit the position and press [Near]

to save or [Far] to cancel.

EDIT PRESET LABEL: Press [Near] to edit Label shown on monitor

when preset runs. Max. 10 characters are allowed. Use [Left/Right/

Up/Down] to move the character selector and press [Near] to enter

a character. Select OK and then press [Near] to confirm Label.

CAM ADJUST [GLOBAL/LOCAL]: Select GLOBAL to use the WB and

AE settings that are set in this camera for this preset. Select LOCAL

and press [Near] to define custom WB or AE settings for this preset.

eLineTechnology.com

Advertising
This manual is related to the following products: