3 ceiling mounting (indoor only), En gl is h – eLine Technology ANPTZ-70-10DN User Manual

Page 17

Advertising
background image

11

Installation

En

gl

is

h

4.3 CEILING MOUNTING (INDOOR ONLY)

Camera is not weatherproof if installed using this method.

Use the included wall mount or accessory ceiling mount (not

included) for outdoor installations.

Make sure to disconnect power before installing the camera.

Camera will begin moving immediately when power is connected.

To install the camera:
1. You must remove the camera from the included wall mount for indoor

ceiling mounting. To do so:
• Rotate the dome cover counterclockwise to remove.
• Remove the base attachment screws (3x) and remove the camera

from the camera base.

• Remove the camera base by removing the camera attachment screws

inside the wall mount (4x).

• Disconnect the video and alarm cables from the camera.

1

12

Installation

2. If necessary, change the camera’s ID and protocol information. See

“Changing Protocol Information” on page 5.

3. Remove the adhesive from the

foam pad. Remove the cutouts

for the cables and mounting

screw holes and attach the

foam pad to the bottom of the

camera base with the cutouts

aligned with the screw and

cable holes.

3

Foam Pad

Cable and

mounting screw

cutouts

4. A. If you are running the

cables through the surface,

remove the rubber plug on the

bottom of the camera base and

run the video cable and the

alarm cable connectors

through the bottom cable hole.

Bottom cable

hole

4A

Video and Alarm Cable

OR:

B. If you are running cables

through the side of the

camera, unscrew the side

conduit cap with a flathead

screwdriver, and run the

video cable and alarm cable

connectors through the

conduit hole.

Conduit hole

4B

Video and

Alarm cable

eLineTechnology.com