Model MT 3810

Section 1 Introduction

1-3

Table 1-2 Model MT 3810 Pressure Ratings

617°F

134

448

600°F

140

450

500°F

170

480

400°F

195

515

300°F

215

560

Flange Rating*

150 lb.

300 lb.

200°F

240

620

-20°F to 100°F

275

720

316/316L Stainless Steel (psig at indicated temperature)

Table 1-1 Model MT 3810 Capacities, Pressure Drop and Viscosity Immunity Ceiling

617°F

1200

1200

1200

1000

600°F

1200

1200

1200

1000

500°F

1300

1300

1300

1100

400°F

1400

1400

1400

1200

300°F

1400

1400

1400

1200

Threaded NPT

7 & 8

10

12

13

200°F

1500

1500

1500

1300

-20°F to 100°F

1500

1500

1500

1300

316L Stainless Steel (psig at indicated temperature)

*Flanges are dual certified 316/316L Stainless Steel

CONNECTION SIZE

FLOAT MATERIAL STAINLESS STEEL 316L

METER

DIN

ANSI

FLOAT

WATER

AIR

1,2

Press Drop Press Drop VIC (cSt) Max. Visc

PED

SIZE

DN mm

inches

CODE

l/h

gpm

scfm

nm3/h

mbar

inches WC

(cSt)

(cSt)

Category

15

1/2"

A

25

0.11

0.49

0.78

30

13

1

40

SEP

B*

65

0.28

1.2

2

30

13

1

20

SEP

C

130

0.59

2.4

3.7

30

13

1

120

SEP

D*

200

0.88

3.7

5.8

35

15

1

20

SEP

15

1/2"

A

250

1.1

5.2

8.2

45

19

2

250

SEP

B

400

1.7

7.7

12

55

23

1

180

SEP

C

650

2.8

11

18

60

25

2

475

SEP

D

1000

4.4

21

33

130

53

1.5

250

SEP

25

1"

A

1200

5.2

19

30

60

25

5

475

CAT I, II or III

B

1500

6.6

31

49

70

29

1.5

400

CAT I, II or III

C

2400

10

41

65

85

35

7

475

CAT I, II or III

D

3500

15

65

100

155

63

4

475

CAT I, II or III

40

1 1/2"

A

4000

17

67

100

50

21

50

475

CAT I, II or III

B

6000

26

94

140

60

25

30

475

CAT I, II or III

C

8000

35

150

230

150

61

2

475

CAT I, II or III

D

10000

46

210

330

300

121

2

475

CAT I, II or III

50

2"

A

6500

28

100

160

50

21

50

475

CAT I, II or III

B

9500

41

160

250

60

25

50

475

CAT I, II or III

C

12000

55

200

310

100

41

2.5

475

CAT I, II or III

D

20000

88

390

620

300

121

1

475

CAT I, II or III

1. Air flows in scfm are given at 70°F and 14.7 psia

2. Air flows in nm3/h are given at 0°C and 1.013 bar (a)

3. *Minimum operating pressure required 7 psig / 0.48 bar

13

7

8

10

12

Size

Indicator Only

Indicator with Alarm

Indicator with Transmitter

-58° thru 420° F

-22° thru 320° F

-22° thru 195° F

-50° thru 215° C

-30° thru 160° C

-30° thru 90° C

3810 Minimum and Maximum Ambient Temperature

Indicator Only

Indicator with Alarm or Transmitter

-22° thru 150° F

-30° thru 65° C

7 thru 13

-22° thru 150° F

-30° thru 65° C

Table 1-3 Maximum and Minmum Fluid Temperature at 104

o

F (40

o

C) Ambient

Advertising