English, 4 soft-start function – Burkert Type TAT002 User Manual

Page 10

Advertising
background image

8 - 0911

english

Sensor

Lower limit

Upper limit

NTC

-40 °C

110 °C

PTC

-50 °C

150 °C

Pt100

-200 °C

600 °C

TcK

0 °C

1300 °C

TcJ

0 °C

600 °C

TcS

0 °C

1400 °C

MEASUREMENT LIMITS FOR THE SENSOR TYPES

2.4

SOFT-Start function

dSI =

Increase the set-value in steps (in °C or °F; deactivated with 0).

dSt =

Cycle time for the step-by-step increase of the set-value
(1...3600 sec).

drb =

Increasing the set-value (in °C or °F); the function is deactivated with
drb = 0. This value determines the set-value increase in steps in Kelvin
or °F.

drb

Soft-Start range (in °C or °F; deactivated with 0). If the temperature
is outside this range (on both sides of the set-value),
a new SOFT-Start will be initiated.

dSI

Dynamic set-value increase (in °C or °F; deactivated with 0). This
value determines the step-by-step increase of the set-value of SET1.

dSt

Clock time for the dynamic set-value increase (1...999 sec) or dSl
(SOFT-Start).

Ta =

Measured temperature after device commissioning.

t =

Time axis.