Alarms

tbA

Status of the control relay

oFF = Relay deactivated

after acknowledgement

on = Relay activated

(any button) in any
alarms ituation

AS

Configuration of the alarm

cL = Terminal 5-6 closed

relay at an alarm

oP = Terminal 5-6 closed

Measured value display

LCI

Lower analog

Lower display value at current input

Display value

4 mA or at voltage input 0 V

(-1999...1999)

(only for the inputs 0-20 mA, 0-1V,
0-10 V)

UCI

Upper analog

Upper display value at current input

display value

20 mA or at voltage input 1 V or 10 V

(-1999...1999)

(only for the inputs 0-20 mA, 0-1V,
0-10 V)

rES

Resolution

Selecting display resolution

in = integer (-99...+199)
dEC = 1 decimal point (-99.0...199.0)
cE = 2 digits after the decimal point
(-99.00...199.00)

1,2

irE = large measuring range
(-999...1999)

1,2

UdM

Units

Display of the units directly in the
illuminated display. Regardless of which
controller type is being used:
see

General description

PbC

Type of sensor

Type of inout

Temperature sensor U):

J = Thermoelement „J“; Pt = Pt100;
C = Thermoelement „K“; Ptc = PTC;
S = Thermoelement „S“; ntc = NTC

Current / voltage input

cur = 4...20 mA; 0-1 = 0...1 V;

(AU)

10 = 0...10 V

1

Only for devices with an input of 4...20 mA or 0...1 V or 0...10 V

2

Only for current or voltage input

ATTENTION!

If rES is changed at a later time, the following parameters must
be checked::
SET, Hy1, LS1, uS1, ALL, ALu, ALH, LCi, uCi, LAo, uAo, HES

NOTE

Selecting a decimal point is not possible for thermocouples.