English, 6operation of the hand held terminal, 1 display and keyboard functions – Burkert Type 1094 User Manual

Page 16: Keys, Display

Advertising
background image

14 - 1094_400

english

ENTER

DATA

AUTO

burkert

1094

6

OPERATION OF THE HAND HELD TERMINAL

The self adaptation set type MKEN-1094 is an indepen-
dent device to measure the vapour flow and vapour
quantity and can be used as a calibration instrument for
vapour recovery systems with control electronics Type
1094. A modified gas meter is used as a flow meter.

All functions of control electronics Type 1094 can be
displayed and controlled. The set parameters can be
displayed and adjusted. The self adaptation can also be
started.

The hand held terminal is powered by the vapour
recovery control electronics. Also batteries can be
supplied so it can be used as an independent flow
meter.

6.1

Display and Keyboard Functions

The control unit features a LCD-display providing 2x16 characters and 8 keys.

ENTER

DATA

AUTO

Increase of actual value

Reduction of actual value

Shift to the next/last parameter

Confirmation of set value

Switch between the setting operation and the display of
the actual value

Start/stop of test measurements

Start/stop of self adaptation

Keys

The name of the displayed value is indicated in the upper line of the display.
The lower line provides a 4 digit display for the operation mode on the left, a 4
digit indication of the displayed value in the centre and the unit of the displayed
value on the right.

Display

Advertising