6.6.6 Test Mode PRTother: Wet Measurement (Version C)

Input

Selection

ENTER

DATA

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

Display (2-lines)

V4.1

Operator?

INIT

PRTother

Fuel flow
ACT.

00,0

l/min

Dispenser No
TEST

001

Product
TEST

BF95

T amb
TEST

24,0

° C

Dispensing done?
TEST

<ENTER>

Fuel Vol
TEST

25,0

Litre

Vapor Vol
TEST

25,0

Litre

V/R-Ratio
TEST

100

%

Date
TEST

21.08.97

Remark

Select operator mode

Display mode

Insert 0 ... 099

Super / BF 98 / BF 95 /
Diesel

Ambient temperature is
measured

25 l fuel is dispensed

Change if more or less
then 25l is dispensed

Comparable value
HC-vapor is sucked

Select position
Select number