Figure 4: Vapor Recovery with Proportional Valve 2832 (dry)

Legend:

1

Hand held terminal

2

Gas meter

3

Dispensing nozzle
(with adapter)

4

Dispenser

5

Control electronics

6

Proportional valve 2832

7

Vacuum pump

8

Operating motor for the vacuum pump

9

Storage tank

10 Printer

3.1.2 Automatically adjustable Systems

Because of the inconveniences with the “wet” adjustment and checking of such
systems, Bürkert developed microprocessor controlled systems, which can be
adjusted without gasoline flow.
The control of the vapor flow is accomplished either through a proportional valve

(e.g. Bürkert type 2832, Figure 4) or through a speed controlled pump (Figure 5).