english

Display (2-lines)

V4.1

Operator?

INIT

CHECK-

1094

Fuel flow
ACT.

40,0

l/min

Vapor flow Max
TEST

46,0

l/min

Vapor flow 40
TEST

44,0

l/min

C-factor

40

TEST

110

%

Recovery rate 40
TEST

110

%

Corr. VR

40

TEST

100

%

Vapor flow 40
ACT.

44,0

l/min

6.6.3 Test Mode Evaluation, Service und Check-1094

Input

Selection

ENTER

DATA

Remark

Selecting the operator mode

Display mode

Vapor flow

Vapor flow

Correction factor

Recovery rate

Correct Recovery rate

Return to display mode

DATA

DATA

First the maximum Vapor flow is established. After this the simulation of the fuel
flow starts. It begins with 40 l/min is changed by pressing the keys
The simulated fuel flow is displayed in the upper right corner.