English, 4technical data – Burkert Type 8623 User Manual

Page 6

Advertising
background image

4 - 8623

english

4

TECHNICAL DATA

1)

The Type 8623-B control unit is not included in the delivery of the Type 8623

compact flow controller

Operating voltage

24 V DC

Power consumption

max. 1,5 W

Output current

max. 1,0 A

Operating temperature

-10 to + 60 °C

Noise resistance

to EN50082-2

Noise emission

to EN50081-2

Inputs:
Signal inputs

2 frequency inputs 2 to 625 Hz

Accuracy

±1%

Type of signal

Sinusoidal, square wave, triangular
(

300 mV

ss

)

1 Standard signal input

4 - 20 mA

Connection

in unit: 7-pole terminal + PE
Wire cross-section max. 0,5 mm²
PG 9 fitting;
Cable

φ

6 - 7 mm

Outputs:
Cable outlet

can be turned in 90° steps

Number of terminals

2 poles and earth

Type of contact

Surface contact, similar to a flat plug
(DIN 46 247/48)

Controller:
Control algorithm

PI-Controller

Sampling time TA

40 ms

Amplification factor KP

0 ... 99,99

Integral action time TN

0,1 ... 199,99 s

Integral action time 2

0,0 ... 1999,9

Ratio

0,01 ... 9,99

Calibration

0 ... 199,99

Housing:
Degree of protection

IP 65

Material / Mounting

Polyamide / M3 x 45 mm cheesehead screws

Dimensions / Weight

32 x 90 x 41,5 mm / approx. 50g

Order No.

134 072 K

1)

Control unit Type 8623-B for compact flow controller
Order No.

134 052 P