Burkert Type S020 User Manual

Page 16

Advertising
background image

16

Technicaldata

Type S020

Table 11: Dimensions of the S020 fitting with welding end connections acc. to EN ISO 1127 / ISO 4200, SMS 3008, BS 4825/ASME BPE

or DIN 11850 range 2, for measuring devices with a clamp connection

dn [mm]

p [mm] A [mm] standard

d [mm] s [mm]

A

P

D

S

32

-

130

EN ISO 1127 / ISO 4200 42.4

2

40

-

130

EN ISO 1127 / ISO 4200 48.3

2

42.5

110

SMS 3008

38

1.2

43.7

120.6

BS 4825 / ASME BPE

38.1

1.65

-

120

DIN 11850 range 2

41

1.5

50

-

180

EN ISO 1127 / ISO 4200 60.3

2

49.3

164

SMS 3008

51

1.2

50.6

146

BS 4825 / ASME BPE

50.8

1.65

-

160

DIN 11850 range 2

53

1.5

65

-

220

EN ISO 1127 / ISO 4200 76.1

2

54.4

210

SMS 3008

63.5

1.5

55.4

158.8

BS 4825 / ASME BPE

63.5

1.65

-

210

DIN 11850 range 2

70

2

80

-

260

EN ISO 1127 / ISO 4200 88.9

2.3

60.7

220

SMS 3008

76.1

1.6

62

171.5

BS 4825 / ASME BPE

76.2

1.65

-

260

DIN 11850 range 2

85

2

100

73.8
77.1

209.6

BS 4825 / ASME BPE

101.6

2.11

310

DIN 11850 range 2

104

2

English