Technicaldata

Type S020

6.4.6. K factors (in pulse/litre) for saddles

When the dimensions of the pipe are slightly different from dimensions d and s given in the table, recalculate the K factor using one of
the formulae in chap. 6.4.2.

If the measuring device does not automatically convert the K factor, use the following conversion formulae before setting the para-
meters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546

Table 19: K factors, external diameters and theoretical cross-sections of saddles

measuring device

inserted

8020, 8024, 8025, 8026

8041, 8045

external diameters and theoretical cross-sections

material of the pipe

pVc

pe / pp

pVc

pe / pp

d

pVc

[mm]

s

pVc

[mm]

d

pp

[mm]

s

pp

[mm]

dn

50

14,2 (L)

15,6 (L)

10,4 (L)

9,28 (L)

63

4,7

63

5,8

65

11,2 (L)

12,3 (L)

14,5 (L)

12,9 (L)

75

5,5

75

6,9

80

7,37 (L)

7,80 (L)

21,3 (L)

20,4 (L)

90

6,6

90

8,2

100

4,83 (L)

5,29 (L)

33,0 (L)

30,4 (L)

110

8,1

110

10

110

3,45 (L)

-

44,7 (L)

-

125

9,2

-

-

125

2,55 (L)

3,10 (L)

63,7 (L)

52,1 (L)

140

10,3

140

12,8

150

1,67 (L)

2,03 (L)

137 (L)

78,8 (L)

160

6,2

160

14,6

180

1,08 (L)

1,37 (L)

197 (L)

116 (L)

200

9,6

200

18,2

200

0,80 (L)

1,07 (L)

290 (L)

147 (L)

225

8,6

225

20,5

(L): long sensor version