Burkert Type S020 User Manual

Page 31

Advertising
background image

31

Installationandcommissioning

Type S020

50 x DN 5 x DN

40 x DN 5 x DN

25 x DN 5 x DN

20 x DN 5 x DN

18 x DN 5 x DN

15 x DN 5 x DN

With regulating valve

Pipe with 2 elbows at 90° in 3

dimensions

Pipe with 2 elbows at 90°

Pipe with 1 elbow at 90° or 1

T-piece

With pipe expansion

With pipe reduction

Fig. 7: Upstream and downstream distances depending on the

design of the pipes.

To measure the flow, use a flow conditioner, if necessary, to
obtain the best accuracy.

For all types of measurement, respect the following additional
assembly conditions to ensure that the measuring device ope-
rates correctly (Fig. 8 and Fig. 9) and prevent the formation of air

bubbles in the pipe and the pipe filling system on the measuring
device.

Correct

Incorrect

Correct

Incorrect

Flow direction

Fig. 8: Additional recommendations on installation

English

Advertising
This manual is related to the following products: