K factors (in pulse/litre) for t fittings and wel, Ding sockets used with a 8041 or a 8045 with, Clamp connection – Burkert Type S020 User Manual

Page 23: A 8020, 8024, 8025 or 8026

Advertising
background image

23

Technicaldata

Type S020

6.4.4. K factors (in pulse/litre) for T

fittings and welding sockets used
with a 8041 or a 8045 with clamp
connection

Table 17: K factors of the T fittings for measuring devices with clamp

connection

Type of connection

and standard

DN40

DN50

DN65

DN80

DN100

acc. to SMS 3008 5.23

10.4

15.9

24.7

-

acc. to BS 4825 /
ASME BPE

5.33

10.4

16.7

25.7

50.3

acc. to DIN 11850

range 2

-

-

-

-

52.7

acc. to ISO 4200

-

-

-

-

-

6.4.5. K factors (in pulse/litre) for T fittings

used with a 8020, 8024, 8025 or
8026

If the measuring device does not automatically convert the K
factor, use the following conversion formulae before setting
the parameters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546

Two versions of the S020 in DN15 and DN20 exist, having
different K factors.
Only version 2, identified by the "v2" marking, is available
from March 2012. The "v2" marking can be found:
• on the bottom of the DN15 fitting in plastic:

V2

• on the side of the DN15 or DN20 fitting in metal:

V2

Do not use a fitting S020 in sizes DN6, DN8, DN15, DN15
Version 2 (V2) or DN20 Version 2 (V2) with a paddle-wheel
flowmeter types 8020, 8024, 8025, 8026.

English

Advertising
This manual is related to the following products: