Installation onto the pipe, Recommandations for installing the s020 fitting, On the pipe – Burkert Type S020 User Manual

Page 30

Advertising
background image

30

Installationandcommissioning

Type S020

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

-20

0

+20 +40 +60 +80 +100 +120

PVDF (PN10)

PVC (PN10)

PP (PN10)

T (°C)

P (bar)

PVC + PP

PVDF

+150

DN100 for measuring

devices with clamp connection

(PN10)

Metal

(PN16)

1)

1)

Except DN100 for measuring devices with clamp connection

Fig. 5: Fluid pressure / temperature dependency curves for T

fittings used on their own

7.2.

installation onto the pipe

7.2.1. recommandations for installing the

S020 fitting on the pipe

To measure the pH or the oxidation reduction potential, install
a U-shaped bypass in order to prevent the electrode drying out
and to allow calibration without stopping the process.

Fig. 6: Bypass installation of the fitting

For measuring the flow and depending on the design of the
pipes, respect the minimum distances in accordance with the
standard EN ISO 5167-1, from which the diagrams in Fig. 7 are
excerpted.

English

Advertising
This manual is related to the following products: