Ampro Corporation XTX 820 User Manual

Page 33

Advertising
background image

Chapter 3

Hardware

XTX 820

Reference Manual

27

Pin #

Signal

Description

47

AD15

Address/Data bus 15 – Refer to pin-23 for more information.

48

ASGND

Analog Ground – This ground is used for the sound controller and an
external amplifier to achieved the lowest audio noise levels.

49

CBE1*

Bus Command and Byte Enable 1 – Refer to pin-31 for more information.

50

AOUT_R

Stereo Line Output Right channel – This output signal has a nominal level of
1 volt RMS into 10k impedance load. This output signal can not drive low-
impedance speakers directly

51

VCC2

+5 volts +/-%5

52

VCC3

+5 volts +/-%5

53

PAR

PCI bus Parity bit – This signal is the even parity bit on AD[31:0] and
CBE[3:0]*.

54

SERR*

System Error – This signal is for reporting address parity errors.

55

PERR*

Parity Error – This signal is driven by the PCI target during a write to
indicate a data parity error has been detected.

56

RESERVED

Reserved

57

PME*

Power Management Event – This signal is an optional signal that can be
used by a device to request a change in the device or system power state.

58

USB2-

Universal Serial Bus Port 2 Data Negative Polarity

59

LOCK*

Lock – This signal indicates an operation that may require multiple
transactions to complete.

60

DEVSEL*

Device Select – This signal is driven by the target device when its address is
decoded.

61

TRDY*

Target Ready – This signal indicates the selected device’s ability to
complete the current cycle of transaction. Both IRDY* and TRDY* must be
asserted to terminate a data cycle.

62

USB3-

Universal Serial Bus Port 3 Data Negative Polarity

63

IRDY*

Initiator Ready – This signal indicates the master’s ability to complete the
current data cycle of the transaction.

64

STOP*

Stop – This signal is driven by the current PCI target to request the master to
stop the current transaction.

65

FRAME*

PCI bus Frame access – This signal is driven by the current master to
indicate the start of a transaction and will remain active until the final data
cycle.

66

USB2+

Universal Serial Bus Port 2 Data Positive Polarity

67

GND

Ground

68

GND

Ground

69

AD16

Address/Data bus 16 – Refer to pin-23 for more information.

70

CBE2*

Bus Command and Byte Enable 2 – Refer to pin-31 for more information.

71

AD17

Address/Data bus 17 – Refer to pin-23 for more information.

72

USB3+

Universal Serial Bus Port 3 Data Positive Polarity

73

AD19

Address/Data bus 19 – Refer to pin-23 for more information.

74

AD18

Address/Data bus 18 – Refer to pin-23 for more information.

75

AD20

Address/Data bus 20 – Refer to pin-23 for more information.

Advertising