XTX 820

Pin #

Signal

Description

60

ERR*

HDSEL*

Parallel Error – This is a status output signal from the printer. A low state
indicates an error condition on the printer.

Floppy Head Select – Selects the side for Read/Write operations (0 = side 1,
1 = side 0)

61

IRTX

IR Transmit Data (HPSIR or ASKIR)

62

PD6

Parallel Port Data 6 – This signal (0 to 7) provides a parallel port data signal
and is the printer data MSB.

63

RXD2

Receive Data 2 – Serial port 2 receive data in.

64

INIT*

DIR*

Parallel Initialize* – This signal initializes the printer. Output in standard
mode, I/O in ECP/EPP mode.

Floppy Direction – Direction of head movement (0 = inward motion,
1 = outward motion).

65, 66

GND

Ground

67

RTS2*

Request To Send 2 – Indicates Serial port 2 is ready to transmit data. Used
as hardware handshake with CTS2 for low level flow control.

68

PD5

Parallel Port Data 5 – Refer to pin-58 and 80 for more information.

69

DTR2*

Data Terminal Ready 2 – Indicates Serial port 1 is powered, initialized, and
ready. Used as hardware handshake with DSR2 for overall readiness.

70

SLCTIN*

STEP*

Select In – This output signal is used to select the printer. I/O pin in
ECP/EPP mode.

Floppy Step – Low pulse for each track-to-track movement of the head.

71

DCD2*

Data Carrier Detect 2 – Indicates external serial device is detecting a carrier
signal (i.e., a communication channel is currently open). In direct connect
environments, this input is driven by DTR2 as part of the DTR2/DSR2
handshake.

72

PD4

DSKCHG*

Parallel Port Data 4 – Refer to pin-58 and 80 for more information.

Floppy Disk Change – Senses the drive door is open or the diskette has been
changed since the last drive selection.

73

DSR2*

Data Set Ready 2 – Indicates external serial device is powered, initialized,
and ready. Used as hardware handshake with DTR2 for overall readiness.

74

PD3

RDATA*

Parallel Port Data 3 – Refer to pin-58 and 80 for more information.

Floppy Read Data – Raw serial bit stream from drive for read operations.

75

CTS2*

Clear To Send 2 – Indicates external serial device is ready to receive data.
Used as hardware handshake with RTS2 for low level flow control.

76

PD2

WP*

Parallel Port Data 2 – Refer to pin-58 and 80 for more information.

Floppy Write Protect – Senses the diskette is write protected.

77

TXD2

Transmit Data 2 – Serial port 2 transmit data out

78

PD1

TRK0*

Parallel Port Data 1 – Refer to pin-58 and 80 for more information.

Floppy Track 0 – Sense detects the head is positioned over track 0.

79

RI2*

Ring Indicator 2 – Indicates external serial device is detecting a ring
condition. Used by software to initiate operations to answer and open the
communications channel.