FS10 Series

Fluid Components International LLC

5

Flow Direction Arrow

Sensors perpendicular

“A” (Active) mark

Upstream

Flow Direction

Sensors parallel

Left to Right Flow Example in 1/4 and 3/8 inch tube tees

For optimum sensitivity in low flow applications, probes should

be installed with the “A” (Active) sensor positioned upstream.

Horizontal lines: gas or liquid.
Vertical lines:

gas - flow must be down

liquid - flow must be up

Right to Left Flow Example in 1/2 inch or greater tube or

pipe tee

Probes mounted into 1/2 inch or greater tees are installed with

the sensors positioned perpendicular to the flow path in the

tee. “A” (Active) should be facing up in side mount horizontal

configurations. These sensors may also be marked with a flow

direction arrow.

Mounting Orientation

Diagram 1