23

Tube Replacement and Centering

Removing the Old Pump Tube

1. Turn pump off.

2. Remove screws and then the cover by lifting the side

opposite the tube fittings.

3. Set the feed rate dial on a low setting and leave on this

setting until finished.

4. Turn the pump on and let it run until one of the three slots

in the roller assembly lines up with the bottom tube fitting
(suction side).

BEST PRACTICE

Factory recommended

Prior to tube removal, pump water
through tube to remove chemical.

Continued...