27

IMPORTANT!

Key for optimum performance

Avoid rotating wrist, which
can result in a twisted tube
that will not center. Do not
force the tube and be careful
of your fingers.

NOTE

Additional information

A used tube will stretch
approximately 3/4 of an inch
over its life.
The new tube will
appear to be stiff and short.
Follow directions to allow
rollers to stretch tube into
place.

4. When the tube reaches the top housing slot, turn pump off.

Turn dial ring to 10, hold tube fitting firmly, and turn
pump on.

Allow rollers to stretch tube into place while guiding the
tube into the slot.

5. Turn the pump off.

Continued...