5.1.1 Eclipse HX-Omega and Eclipse HX-Median

The Eclipse HX-Omega and HX-Median matrices (matrix frames) are supplied with two
internal Euro Cassette plug-in power supplies. When both power supplies are connected to
AC mains power (using the IEC power connectors on the rear panel), the matrix will continue
to operate even if one of the AC power sources fails.

A fully equipped Eclipse HX-Omega or HX-Median matrix requires 100 - 240 VAC at 50 - 60
Hz
with a maximum dissipation of 300 W.

5.1.2 Eclipse HX-Delta

The Eclipse HX-Delta's power is provided by two external 12V power supply units (for
redundancy). The power supplies have separate connections to the rear of the matrix (see
Figure 3: Eclipse HX-Delta rear panel).

Each of the power supplies must be connected to a dedicated branch of AC mains power.
The matrix will continue to operate even if one of the power supply units fails.

When the matrix is installed to the rack, connect the power cables from the external power
supplies to the power connectors on the rear of the matrix.

The power cables connecting the supplies to the matrix are capable of sustaining a pull test
of 10 Newtons. The power cables are secured to the matrix by latching connectors.

When the matrix is connected to the power supplies, connect the power supplies to AC
mains power. PSU brackets are available that can be mounted to the 19-inch frame. The
PSU brackets can be mounted individually or as a pair.

A fully equipped Eclipse HX-Delta matrix (2 CPU cards, 4 interface cards and 3 interface
modules) requires 100 - 240 VAC at 50 - 60 Hz with a maximum dissipation of 175W.

5.1.3 Eclipse HX-PiCo

The Eclipse HX-PiCo matrix has two internal power supply units. One power supply unit can
power an entire matrix; the second unit provides a backup in case of equipment failure.

In addition, the two supplies have separate IEC connectors to AC mains power, and are
designed for completely automatic and transparent changeover between supplies in the
event of an outage on one of the AC mains circuits.

The power supplies are universal, operating over a voltage range of 100 - 240 VAC at
50 - 60 Hz.

An HX-PiCo requires 100 - 240 VAC at 50 - 60 Hz with a maximum dissipation of 40 W.

Note:

The same information is applicable to the E-32, the immediate predecessor of the
Eclipse HX-PiCo.