5.3.2 IMF-102

The IMF-102 has an internal power supply and a rear panel connector for connecting
redundant power. The power supply is universal, operating over a voltage range of 90 - 250
VAC
. The maximum dissipation is 20W.

Tip:

An additional power supply can be added for redundancy by connecting a PSU-101

power supply to the power connector on the rear panel.

For more information, see the IMF-102 Interface Module Instruction Manual.

5.3.3 Current capacities and consumption

The current capacities of the power supplies are as follows:

+9 V analog 3.0 A

-9 V analog 3.0 A

The following chart provides the current drain of the +/- analog power supplies for interface
modules and the IMF-3 interface frame.

Note:

Some devices, such as interface modules, have a varying current depending on the
operation of features. In Eclipse HX devices where it is possible to activate all operating
features of all components used, use the maximum current column for planning.

Component

Average current

Maximum

IMF-3

0.20 A

0.20 A

CCI-22

0.00 A

0.00 A

FOR-22

0.07 A

0.15 A

TEL-14

0.28 A

0.37 A

RLY-6

0.10 A

0.15 A

GPI-6

0.02 A

0.02 A

AES-6

0.16 A

0.16 A

Table 6:

Interface current consumption