Clear-Com HX System Frames User Manual

Page 61

Advertising
background image


Key to Figure 19: Wiring an IMF-3 rear panel to a TEL-14 interface module

Connector

Instruction / description

A

The upper DB-9M connector is used to connect to the first telephone
line, line A.

B

The upper RJ-45 connector is then used to connect telephone line A to
the matrix frame.

C

The lower DB-9M connector is used to connect to the second telephone
line, line B.

D

The lower RJ-45 connector is used to connect telephone line B to the
matrix frame.

Table 16: Key to Figure 20; Wiring an IMF-3 rear panel to a TEL-14 interface module

Note:

To allow use of a common RJ-11 terminated telephone line, Clear-Com provides two DB-9F
to RJ-11 adapters (Clear-Com part 770025).

For internal dip-switch settings and adjustments, see the TEL-14 manual.

Wiring a TEL-14 interface to an IMF-102 interface frame

On the rear of the IMF-102, there are two sets of four connectors each, arranged
horizontally.

Figure 23: Wiring an IMF-102 rear panel assembly to a TEL-14 interface

Ch. A

Matrix

Ch. A

I / O

Ch. B

Matrix

Ch. B

I / O

Ch. A

Matrix

Ch. A

I / O

Ch. B

Matrix

Ch. B

I / O

A

B

C

D

61

Eclipse HX Matrix Frame Installation Guide

Advertising