5.2 Powering user panels

5.2.1 V-Series panels

V-Series panels, including expansion panels, have an external DC power supply.

The power supply is universal, operating over a voltage range of 100 - 240 VAC at 50 - 60
Hz
. The maximum dissipation is 50W.

5.2.2 I-Series panels

I-Series panels have an internal power supply, with a removable AC power cable.

The power supply is universal, operating over a voltage range of 90 - 245 VAC and
50 - 60 Hz. The maximum dissipation is 40W.

5.3 Powering interface frames

5.3.1 IMF-3

The IMF-3 interface frame requires an external PSU-101 power supply
(see Figure 2: PSU-101 power supply for IMF-3).

Usually, one PSU-101 power supply unit is required for approximately every two IMF-3
frames. This requirement may differ where:

The IMF-3 is hosting a large number of CCI-22 paryline interface modules,

which require no DC power from the IMF-3 frame (the modules are powered from
the partyline connection).

However, even if the IMF-3 only contains CCI-22 interface modules, a PSU-101
power supply is still required to power the circuitry on the rear panel of the IMF-3.

The IMF-3 is hosting multiple TEL-14 telephone interface modules. An IMF-3

interface frame can only power eight TEL-14 interfaces on one PSU-101 power
supply. If more TEL-14 interface modules are required, they must be installed in a
second IMF-3 frame with a second power supply.

28

Eclipse HX Matrix Frame Installation Guide